LFT-G® PA6 LGF40 | 40% Long Glass Fiber Polyamide 6

LFT-G® PA6 LGF40 | 40% Long Glass Fiber Polyamide 6

Details
PA6 LGF40 is a 40% long glass fiber reinforced polyamide 6 compound supplied as injection-molding pellets, providing long-fiber reinforcement and higher stiffness for molded parts in a PA6 matrix.
This page covers long glass fiber reinforced PA6 (PA6 LGF40), not conventional short glass fiber reinforced PA6 GF40 compounds.
Standard pellet length is 10–12 mm; custom lengths are available from 6–25 mm.
√ 189 MPa Tensile Strength (ISO 527)
√ 9,569 MPa Flexural Modulus (ASTM D-790)
√ 35 kJ/m² Notched Izod (ISO 180)
√ 208°C HDT (ISO 75-2)
√ 1.43 g/cm³ Density (ASTM D-792)
A 25 kg trial order can be discussed.
Category
PA6 LGF Compound
 
Send Inquiry
Chat Now
Description
Technical Parameters

Technical Data

Property Specification
Product Grade PA6 LGF40
Base Resin Polyamide 6 (PA6 / Nylon 6)
Fiber Type Long Glass Fiber
Fiber Content 40%
Color Black and Natural
Form Injection-Molding Pellets, 10–12 mm
Property Value Test Standard
Density 1.43 g/cm³ ASTM D-792
Molding Shrinkage 0.1–0.3% ASTM D-955
Tensile Strength 189 MPa ISO 527
Tensile Modulus 12,693 MPa ISO 527
Tensile Elongation 1.7–2.5% ISO 527
Flexural Strength 281 MPa ASTM D-790
Flexural Modulus 9,569 MPa ASTM D-790
Charpy Notched Impact Strength 34 kJ/m² ISO 179
Heat Deflection Temperature 208°C ISO 75-2 (1.8 MPa)
Flammability HB @ 1.5 mm UL-94

Typical values from our factory TDS LFT-PA6-LGF40-NG04-Datasheet-TDS.pdf, A3, Revised 30/06/2026. Values are typical values from limited laboratory test specimens and are not specification limits.

Use a full-round runner with a minimum diameter of 5–6 mm, make the gate as large as practical, and avoid pin-point gates. The 5–6 mm figure is the runner diameter, not a gate-opening dimension.

The table above lists our A3 factory TDS typical values. Tensile strength and tensile modulus also have ASTM D-638 values - 188 MPa and 12,588 MPa - for same-standard comparison. Notched Izod impact is 35 kJ/m² (ISO 180), or 326 J/m (ASTM D-256); the two Izod figures use different test methods. Charpy notched impact is 34 kJ/m² (ISO 179). The grade has a density of 1.43 g/cm³ and a flexural modulus of 9,569 MPa, per our factory TDS.

PA6 LGF40 vs. Other Reinforced Nylon Materials

PA6 LGF40 is the higher-stiffness grade of the PA6 LGF range, specified when 30% does not meet the stiffness requirement. The comparisons below explain when 40% long glass fiber is the right choice and how it compares with a published competitor grade on matched test methods.

PA6 GF40 vs. PA6 LGF40: When Is a Long-Fiber Upgrade Worth It?

Long glass fiber vs short glass fiber schematic comparison

Long fibres vs. short fibres. Schematic, not to scale.

Property PA6 LGF40 PA6 GF40 short fiber
Glass fiber content 40% 40%
Tensile strength 189 MPa (ISO 527) 159–200 MPa (dry, various suppliers)
Flexural modulus 9,569 MPa (ASTM D-790) 8,270–11,700 MPa (ASTM D-790, various suppliers)
Notched Izod impact 35 kJ/m² (ISO 180) 13–15 kJ/m² (ISO 180, dry)
Density 1.43 g/cm³ 1.43–1.46 g/cm³

Both materials contain 40% glass fiber, but the reinforcement architecture is different: PA6 LGF40 uses long glass fibers that form a skeletal network inside the molded part, while conventional PA6 GF40 uses short fibers. At 40%, tensile strength and flexural modulus overlap with the short-fiber band; the long-fiber advantage shows mainly in notched impact resistance, fatigue, and creep. Pellet length is 10–12 mm; retained fiber length after molding depends on the part and process - we confirm it with a molding trial. Switching from short fiber? Compare the matched data above and validate on your part with a 25 kg trial.

PA6 LGF40 Molding Shrinkage: 0.1–0.3% (ASTM D-955)

Our A3 TDS reports molding shrinkage of 0.1–0.3% (ASTM D-955) for PA6 LGF40-NG04. This value applies to this grade only and varies with flow direction, fiber orientation, part geometry, and processing conditions. Long fibers resist contraction during cooling, so LGF40 generally shows lower and less direction-dependent shrinkage than short-fiber PA6 GF40, but the comparison is qualitative.

PA6 vs. PA66: Choosing the Base Resin

PA6 and PA66 differ first in the base resin, not in the fiber. PA66 generally offers a higher heat deflection temperature and lower moisture absorption than PA6. PA6 LGF40's HDT is 208°C (ISO 75-2, 1.8 MPa) - a grade measurement, not a continuous-use temperature rating. PA6 crystallizes more slowly than PA66, which generally gives a brighter molded surface with less floating fiber; these are tendencies, not absolutes. Need PA66 instead? We supply PA66 LGF in the same long-fiber architecture - ask us for the right grade.

LFT-G PA6 LGF40 vs. PlastiComp Complet® LGF40-PA6

Property LFT-G PA6 LGF40 Complet® LGF40-PA6
Glass fiber content 40% 40%
Tensile strength (ASTM D-638) 188 MPa 235 MPa
Tensile modulus (ASTM D-638) 12,588 MPa 12,931 MPa
Flexural strength (ASTM D-790) 281 MPa 316 MPa
Flexural modulus (ASTM D-790) 9,569 MPa 12,069 MPa
Notched Izod impact (ASTM D-256) 326 J/m 270 J/m
Density (ASTM D-792) 1.43 g/cm³ 1.45 g/cm³

On matched ASTM test methods, Complet® leads on tensile strength, tensile modulus, flexural strength, and flexural modulus. LFT-G leads on notched Izod impact (326 J/m vs 270 J/m). Same resin, same fiber content - compare the numbers directly. Request our TDS or a 25 kg trial to validate it on your part.

Applications of PA6 LGF40

Power Tool Housings

PA6 LGF40 is used in injection-molded power tool housings. The toughened grade PA6 LGF40-NG04TA passed a 2 m drop test at -20°C for 20 drops in heavy-duty rotary hammer housings. Selected on its A3 TDS values: tensile 172 MPa, Izod 40 kJ/m², HDT 207°C.

Cordless nail gun, power tool housing

Automotive Mirror Housings

PA6 LGF40 can be evaluated for automotive side mirror housings and support brackets, subject to vibration, fatigue, and . Housings and brackets face different service conditions and must be validated separately.

Car side mirror housing

Industrial Equipment Support Brackets

PA6 LGF40 can be evaluated for industrial equipment support brackets, subject to load, creep, and dimensional validation.

Black molded support bracket

Best where the long-fiber network stays intact. Vibration-welded joints such as air intake manifolds are the exception - welding breaks the fiber network at the seam, so short-fiber grades fit those parts better. For sustained high-temperature service near the engine compartment, validate on your part first: HDT is 208°C, a grade measurement, not a continuous-use rating. Ask us to confirm fit for your part.

Injection Molding Processing Guide

Injection molding process steps

  1. Drying- Dry at 80–90°C for 2–4 hours and keep moisture below 0.05% before molding. Drying is the most critical step: wet PA6 loses performance directly at high temperature, as amide bonds break down.
  2. Melt- Melt temperature 243–270°C.
  3. Injection- Injection pressure 69–124 MPa. Use a metering screw with an L/D ratio of 18:1–24:1 and a large open nozzle; keep feeding at about 40%.
  4. Gate and runner- Use a full-round runner with a minimum diameter of 5–6 mm; make the gate as large as practical and avoid pin-point gates.
  5. Mold- Mold temperature 54–93°C. Use a clamping force above 100 tons. Regrind up to 5%. Purge the machine with PE or PP before shutdown.

Grade Selection

Grade Base Resin Fiber Content Color TDS
PA6 HLGF40 (high-performance grade) PA6 40% long glass fiber Black and Natural Download TDS
Inquiry Us
PA6 LGF40-NG04TA (toughened grade) PA6 40% long glass fiber Black and Natural Download TDS
Inquiry Us

High-Performance Grade - HLGF40-NG04

For higher stiffness and strength at the same 40% fiber content, the high-performance grade HLGF40-NG04 is available; both grades have the same HDT of 208°C, so it is a stiffness and strength upgrade, not a heat-resistance upgrade.

Property PA6 LGF40-NG04 PA6 HLGF40-NG04
Tensile strength (ISO 527) 189 MPa 207 MPa
Tensile modulus (ISO 527) 12,693 MPa 13,862 MPa
Flexural strength (ASTM D-790) 281 MPa 307 MPa
Flexural modulus (ASTM D-790) 9,569 MPa 10,866 MPa
Notched Izod (ISO 180) 35 kJ/m² 42 kJ/m²
Charpy (ISO 179) 34 kJ/m² 39 kJ/m²
Density (ASTM D-792) 1.43 g/cm³ 1.44 g/cm³
HDT (ISO 75-2, 1.8 MPa) 208°C 208°C

Toughness-Oriented Option - LGF40-NG04TA

For parts that must survive drops and impacts, the toughened grade PA6 LGF40-NG04TA trades some stiffness and tensile strength for higher notched impact performance.

Property PA6 LGF40-NG04 PA6 LGF40-NG04TA
Tensile strength (ISO 527) 189 MPa 172 MPa
Tensile modulus (ISO 527) 12,693 MPa 12,022 MPa
Flexural strength (ASTM D-790) 281 MPa 270 MPa
Flexural modulus (ASTM D-790) 9,569 MPa 9,533 MPa
Notched Izod (ISO 180) 35 kJ/m² 40 kJ/m²
Charpy (ISO 179) 34 kJ/m² 43 kJ/m²
Density (ASTM D-792) 1.43 g/cm³ 1.43 g/cm³
HDT (ISO 75-2, 1.8 MPa) 208°C 207°C

PA6 LGF40-NG04TA is an alternative for applications prioritizing notched impact performance, such as power-tool housings that must survive drop tests. Compare stiffness on its TDS and confirm fit with a 25 kg trial.

The PA6 LGF flame-retardant grade in our factory TDS is HLGF50-NG05FR, rated UL-94 V0 at 2.0 mm. See the PA6 LGF50 page.

Our factory TDS covers three PA6 LGF40 grades: the standard grade PA6-LGF40-NG04, the high-performance grade PA6-HLGF40-NG04, and the toughened grade PA6-LGF40-NG04TA. For higher stiffness, see PA6 LGF50; for a flame-retardant PA6 LGF grade, see HLGF50-NG05FR on the PA6 LGF50 page. The standard trial quantity is 25 kg for LFT-LGF materials.

FAQ

Q: Is PA6 LGF40 the same as PA6 GF40 short fiber?

A: No. This page covers long glass fiber reinforced PA6 (PA6 LGF40), not conventional short glass fiber reinforced PA6 GF40 compounds. The two materials share resin and fiber content, but their reinforcement architecture and molded-part behavior are different.

Q: What is the difference between PA6 LGF40 and PA6 GF40 short-fiber compounds?

A: Both contain 40% glass fiber, but PA6 LGF40 uses long-fiber reinforcement, while conventional PA6 GF40 uses short fibers. The different reinforcement architectures affect molded-part behavior; compare grade data under matched test methods and conditioning. Pellet length is 10–12 mm; retained fiber length after molding depends on the part and process.

Q: What colors and pellet lengths are available for PA6 LGF40?

A: PA6 LGF40-NG04 is available in black and natural. Standard pellet length is 10–12 mm, with custom lengths from 6–25 mm. Across the PA6 LGF range, HLGF50-NG05FR is available in natural only.

Q: How should PA6 LGF40 be dried, and how does moisture affect it?

A: Dry PA6 LGF40-NG04 at 80–90°C for 2–4 hours and keep moisture below 0.05% before molding. PA6 generally absorbs more moisture than PA66 under comparable conditions; moisture can affect dimensions and mechanical properties. Unreinforced-PA6 saturation figures do not apply to this grade.

Q: What runner and gate design is recommended for PA6 LGF40?

A: Use a full-round runner with a minimum diameter of 5–6 mm. Make the gate as large as practical and avoid pin-point gates; 5–6 mm is the runner recommendation, not a universal gate-opening dimension.

Q: What is the trial order quantity for PA6 LGF40?

A: The standard trial quantity is 25 kg for LFT-LGF materials. Share the application, target properties, color, and molding conditions so the appropriate PA6 LGF grade and trial arrangement can be confirmed.

Q: What should I check before choosing PA6 LGF40?

A: Check service temperature and moisture conditions against the TDS first. HDT is 208°C at 1.8 MPa (ISO 75-2), a grade measurement rather than a continuous-use rating. Measured molding shrinkage is 0.1–0.3% (ASTM D-955), varying with flow direction, fiber orientation, part geometry, mold design, and processing.

Q: Should I upgrade from PA6 GF40 short fiber to PA6 LGF40?

A: Consider switching when a molded part needs long-fiber reinforcement or the short-fiber grade does not meet validated stiffness, impact, or structural requirements. Confirm fit with a molding trial - a 25 kg trial order is available.

Q: When should I choose PA6 LGF40-NG04TA instead of PA6 LGF40-NG04?

A: Choose the toughened grade when the part must survive drops and impacts: it raises notched Izod impact to 40 kJ/m² (ISO 180) and Charpy to 43 kJ/m² (ISO 179), at the cost of lower tensile strength (172 MPa). Verify stiffness against its TDS before switching.

 

 

Request TDS & Trial Sample - PA6 LGF40

Order as: LFT-G® PA6-LGF40-NG04 - 25 kg trial order available.

Email: candyhu@lfrtplastic.com

WhatsApp: +86 139 5009 5707

Send Inquiry

LFT-G team at exhibition

Related Grades

PA6 LGF30

30% long glass fiber PA6 - the balanced structural grade.

Current Grade
PA6 LGF40

40% long glass fiber PA6 - higher stiffness structural grade.

PA6 LGF50

50% long glass fiber PA6 - the maximum stiffness grade.

 

Hot Tags: PA6 LGF40, 40% long glass fiber polyamide 6, LFT-G PA6 LGF40

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!