Technical Data
| Item | Specification |
|---|---|
| Product Grade | PA6 LGF60 |
| Base Resin | Polyamide 6 (PA6 / Nylon 6) |
| Fiber Type | Long Glass Fiber |
| Fiber Content | 60% |
| Color | Black and Natural |
| Form | Injection-Molding Pellets, 10–12 mm |
| Property | Value | Standard |
|---|---|---|
| Density | 1.63 g/cm³ | ASTM D-792 |
| Molding Shrinkage | 0.1–0.2% | ASTM D-955 |
| Tensile Strength | 271 MPa | ISO 527 |
| Tensile Modulus | 19,522 MPa | ISO 527 |
| Tensile Elongation | 1.5–2.5% | ISO 527 |
| Flexural Strength | 380 MPa | ASTM D-790 |
| Flexural Modulus | 14,226 MPa | ASTM D-790 |
| Charpy Notched Impact Strength | 45 kJ/m² | ISO 179 |
| Heat Deflection Temperature | 208°C | ISO 75-2 (1.8 MPa) |
| Flammability | HB @ 1.5 mm | UL-94 |
Typical values from our factory TDS LFT-PA6-LGF60-NG06-Datasheet-TDS.pdf, A3, Revised 30/06/2026. Values are typical values from limited laboratory test specimens and are not specification limits.
PA6 LGF60 delivers a tensile strength of 271 MPa (ISO 527) and a heat deflection temperature of 208°C (ISO 75-2, 1.8 MPa). Tensile strength and tensile modulus also have ASTM D-638 values - 270 MPa and 19,693 MPa - for same-standard comparison. Notched Izod impact is 43 kJ/m² (ISO 180), or 423 J/m (ASTM D-256); the two Izod figures use different test methods. Charpy notched impact is 45 kJ/m² (ISO 179). Density is 1.63 g/cm³ and flexural modulus is 14,226 MPa, per our factory TDS.
PA6 LGF60 vs. Other Reinforced Nylon Materials
PA6 LGF60 is the highest-stiffness grade of the PA6 LGF range, specified when 50% falls short on stiffness or when a part must replace die-cast metal. The comparisons below explain when 60% long glass fiber is the right choice, and how it compares with a published competitor grade.
PA6 GF60 vs. PA6 LGF60: When Is a Long-Fiber Upgrade Worth It?

Long fibres vs. short fibres. Schematic, not to scale.
| Property | PA6 LGF60 | PA6 GF60 short fiber |
|---|---|---|
| Glass fiber content | 60% | 60% |
| Tensile strength | 271 MPa (ISO 527) | 230–255 MPa (dry, various suppliers) |
| Flexural modulus | 14,226 MPa (ASTM D-790) | 18,000–20,000 MPa (ASTM D-790 / ISO 178, various suppliers) |
| Charpy notched impact | 45 kJ/m² (ISO 179) | 18 kJ/m² (ISO 179, dry) |
| Density | 1.63 g/cm³ | 1.70 g/cm³ |
Both materials contain 60% glass fiber. The long-fiber advantage shows mainly in tensile strength and notched impact resistance: tensile strength is 271 MPa, above the 230–255 MPa range for short-fiber grades, and Charpy notched impact is 45 kJ/m², against 18 kJ/m² for a published short-fiber grade. A long-fiber upgrade is worth evaluating when the part must resist repeated impact or sustained load. Switching from short fiber? Compare the matched data above and validate on your part with a 25 kg trial.
PA6 LGF60 Molding Shrinkage: 0.1–0.2% (ASTM D-955)
Our A3 TDS reports molding shrinkage of 0.1–0.2% (ASTM D-955) for PA6 LGF60-NG06. This value applies to this grade only and varies with flow direction, fiber orientation, part geometry, and processing conditions. Long fibers resist contraction during cooling, so LGF60 generally shows lower, less direction-dependent shrinkage than short-fiber PA6 GF60, but the comparison is qualitative.
PA6 vs. PA66: Choosing the Base Resin
PA6 and PA66 differ first in the base resin, not in the fiber. PA66 generally offers a higher heat deflection temperature and lower moisture absorption than PA6. PA6 LGF60's HDT is 208°C (ISO 75-2, 1.8 MPa) - a grade measurement, not a continuous-use temperature rating. PA6 crystallizes more slowly than PA66, which generally gives a brighter molded surface with less floating fiber. Need PA66 instead? We supply PA66 LGF in the same long-fiber architecture - ask us for the right grade.
LFT-G PA6 LGF60 vs. PlastiComp Complet® LGF60-PA6
| Property | LFT-G PA6 LGF60 | Complet® LGF60-PA6 |
|---|---|---|
| Glass fiber content | 60% | 60% |
| Tensile strength (ASTM D-638) | 270 MPa | 255 MPa |
| Tensile modulus (ASTM D-638) | 19,693 MPa | 20,000 MPa |
| Flexural strength (ASTM D-790) | 380 MPa | 407 MPa |
| Flexural modulus (ASTM D-790) | 14,226 MPa | 17,200 MPa |
| Notched Izod impact (ASTM D-256) | 423 J/m | 370 J/m |
| Density (ASTM D-792) | 1.63 g/cm³ | 1.69 g/cm³ |
LFT-G leads on tensile strength (270 vs. 255 MPa) and notched Izod impact (423 vs. 370 J/m, same ASTM D-256 test method), and the grade is lighter (1.63 vs. 1.69 g/cm³). If tensile strength or impact resistance is the deciding property, evaluate our PA6 LGF60 on a 25 kg trial.
Applications of PA6 LGF60
Metal-Replacement Structural Parts
Structural parts that replace die-cast metal need stiffness, strength, and dimensional stability in one molding. PA6 LGF60 delivers a tensile strength of 271 MPa and a tensile modulus of 19,522 MPa, with molding shrinkage of only 0.1–0.2% for tight dimensional control. Typical parts include brackets, housings, and mounting frames. Validate the metal-replacement design on your part with a 25 kg trial.


Gears, Bearings & Transmission Parts
Gears and bearing cages face continuous sliding contact and cyclic loads. The long-fiber network spreads load and resists fatigue cracking, holding tooth and bore dimensions over long service life. Low molding shrinkage (0.1–0.2%) keeps gear geometry stable for quiet, consistent meshing. Typical parts include gear wheels, bearing cages, and transmission housings.
Pump & Valve Components
Pump housings and valve bodies face sustained pressure and chemical exposure. PA6 LGF60 holds part shape under load, and its notched Izod impact of 43 kJ/m² protects thin-wall sections against handling knocks and pressure surges. Typical parts include pump housings, impellers, and valve bodies. Validate the component on your part with a 25 kg trial.

Best where the long-fiber network stays intact. Vibration-welded joints such as air intake manifolds are the exception - welding breaks the fiber network at the seam, so confirm the joint design with us before specifying long fiber for those parts. For sustained high-temperature service near the engine compartment, validate on your part first: HDT is 208°C, a grade measurement, not a continuous-use rating. Ask us to confirm fit for your part.
Injection Molding Processing Guide

- Drying - Dry at 100–120°C for 4–6 hours and keep moisture below 0.1% before molding. Drying is the most critical step: wet PA6 loses performance directly at high temperature, as amide bonds break down.
- Melt - Melt temperature 240–270°C.
- Injection - Injection pressure 90–140 MPa. At 60% fiber loading, melt viscosity is high - use a metering screw with an L/D ratio of 18:1–24:1 and a large open nozzle; keep feeding at about 40%.
- Gate and runner - Use a full-round runner with a minimum diameter of 5–6 mm; make the gate as large as practical and avoid pin-point gates. Design wall thickness at 3.0 mm or above for 60% fiber loading.
- Mold - Mold temperature 80–125°C. Use a clamping force above 100 tons. Regrind up to 5%. Purge the machine with PE or PP before shutdown.
Grade Selection
| Grade | Base Resin | Reinforcement | Color | TDS |
|---|---|---|---|---|
| PA6 HLGF60 (high-performance grade) | PA6 | 60% long glass fiber | Black and Natural | Download TDS Inquiry Us |
High-Performance Grade - HLGF60-NG06
For higher stiffness and strength, the high-performance grade HLGF60-NG06 is available. Its HDT is 210°C, only 2°C above the standard grade's 208°C, so the upgrade is mainly a stiffness and strength upgrade.
| Property | PA6 LGF60-NG06 | PA6 HLGF60-NG06 |
|---|---|---|
| Tensile strength (ISO 527) | 271 MPa | 293 MPa |
| Tensile modulus (ISO 527) | 19,522 MPa | 20,812 MPa |
| Flexural strength (ASTM D-790) | 380 MPa | 420 MPa |
| Flexural modulus (ASTM D-790) | 14,226 MPa | 15,323 MPa |
| Notched Izod (ISO 180) | 43 kJ/m² | 50 kJ/m² |
| Charpy (ISO 179) | 45 kJ/m² | 52 kJ/m² |
| Density (ASTM D-792) | 1.63 g/cm³ | 1.64 g/cm³ |
| HDT (ISO 75-2, 1.8 MPa) | 208°C | 210°C |
Our factory TDS covers two PA6 LGF60 grades: the standard grade PA6-LGF60-NG06 and the high-performance grade PA6-HLGF60-NG06. For lower stiffness, see PA6 LGF50. The standard trial quantity is 25 kg for LFT-LGF materials.
FAQ
1. What is the difference between PA6 LGF60 and PA6 GF60 short-fiber compounds?
Both contain 60% glass fiber, but PA6 LGF60 uses long-fiber reinforcement, while conventional PA6 GF60 uses short fibers. The ferent architectures affect molded-part behavior; compare grade data under matched test methods. Pellet length is 10–12 mm; retained fiber length after molding depends on the part and process.
2. What colors and pellet lengths are available for PA6 LGF60?
PA6 LGF60-NG06 is available in black and natural. Standard pellet length is 10–12 mm, with custom lengths from 6–25 mm.
3. How should PA6 LGF60 be dried, and how does moisture affect it?
Dry PA6 LGF60-NG06 at 100–120°C for 4–6 hours and keep moisture below 0.1% before molding. PA6 generally absorbs more moisture than PA66 under comparable conditions; moisture can affect dimensions and mechanical properties. Unreinforced-PA6 saturation figures do not apply to this grade.
4. What runner and gate design is recommended for PA6 LGF60?
Use a full-round runner with a minimum diameter of 5–6 mm. Make the gate as large as practical and avoid pin-point gates; 5–6 mm is the runner recommendation, not a universal gate-opening dimension. Design wall thickness at 3.0 mm or above for 60% fiber loading.
5. What is the trial order quantity for PA6 LGF60?
The standard trial quantity is 25 kg for LFT-LGF materials. Share the application, target properties, color, and molding conditions so appropriate PA6 LGF grade and trial arrangement can be confirmed.
6. What should I check before choosing PA6 LGF60?
Check service temperature and moisture conditions against the TDS first. HDT is 208°C at 1.8 MPa (ISO 75-2), a grade measurement rather than a continuous-use rating. Measured molding shrinkage is 0.1–0.2% (ASTM D-955), varying with flow direction, fiber orientation, part geometry, mold design, and processing.
7. Is PA6 LGF60 electrically insulating?
PA6 LGF60 is an electrical insulator: glass fiber does not conduct electricity, and the grade is rated HB at 1.5 mm (UL-94). It suits electrical housings and connector parts where insulation is required; confirm the exact electrical requirements against the TDS before specifying it.
Request TDS & Trial Sample - PA6 LGF60
Order as: LFT-G® PA6-LGF60-NG06 - 25 kg trial order available.
Email: candyhu@lfrtplastic.com
WhatsApp: +86 139 5009 5707

Related Grades
Hot Tags: PA6 LGF60, 60% long glass fiber polyamide 6, LFT-G PA6 LGF60