Properties | Test Method | Units | Value |
Physical Property | |||
Specific gravity | ISO1183 | g/cm3 | 1.43 |
Water absorption(23℃,24hr) | ISO62 | % | 0.9 |
Processability | |||
Molding shrinkage | ISO294-4 | % | 0.3-0.5 |
Mechanical properties | |||
Tensile strength | ISO527 | MPa | 165 |
Elongation at break | ISO527 | % | 2.8 |
Flexural strength | ISO178 | MPa | 250 |
Flexural modulus | ISO178 | MPa | |
Charpy impact strength(notched) +23℃ | ISO179(1eA) | KJ/m2 | 20 |
Charpy impact strength(unnotched) +23℃ | ISO179(1eA) | KJ/m2 | 90 |
Thermal properties | |||
Temp.of deflection under load | ISO75f | ℃ | 213 |
Flammability | |||
Flammability | UL94 | HB | |
Electrical properties | |||
Dielectric constant(106Hz) | IEC60250 | 3.1 | |
Dissipation factor(106Hz) | IEC60250 | 0.031 | |
Volume resistivity | IEC60093 | Ω·m | 1 |
Electric strength | IEC60243 | KV/m | 30 |
Arc resistance | IEC61621 | Sec | - |
CTI | IEC60112 | V | 550 |
Reinforced | % | 40 | |
Application:
mechanical parts, automotive cooling fans, heat sink and other rigid impact products
Highlights:
40% glass fiber reinforced. Good rigidity and impact toughness, easy forming
Our Company
![]()

XIAMEN LFT COMPOSITE PLASTIC CO.,LTD.
Focus on (LFT-G, LFRT) R&D and production: PA, PP, TPU, PPS, PBT, PPA,PEI,PEEK long glass fiber & carbon fiber continuous infiltration thermoplastic composite reinforcement series engineering plastics.It can be used in aerospace, automotive, medical equipment, sports equipment, home appliances and other lightweight and cost-effective semi-structural parts that require high performance markets.
Hot Tags: 40% glass fiber reinforced nylon 6 granule, China, manufacturers, suppliers, factory, buy, customized